Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nanotechnology ; 34(27)2023 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-37011598

RESUMO

Time-resolved super-resolution microscopy was used in conjunction with scanning electron microscopy to image individual colloidal CdSe/CdS semiconductor quantum dots (QD) and QD dimers. The photoluminescence (PL) lifetimes, intensities, and structural parameters were acquired with nanometer scale spatial resolution and sub-nanosecond time resolution. The combination of these two techniques was more powerful than either alone, enabling us to resolve the PL properties of individual QDs within QD dimers as they blinked on and off, measure interparticle distances, and identify QDs that may be participating in energy transfer. The localization precision of our optical imaging technique was ∼3 nm, low enough that the emission from individual QDs within the dimers could be spatially resolved. While the majority of QDs within dimers acted as independent emitters, at least one pair of QDs in our study exhibited lifetime and intensity behaviors consistent with resonance energy transfer from a shorter lifetime and lower intensity donor QD to a longer lifetime and higher intensity acceptor QD. For this case, we demonstrate how the combined super-resolution optical imaging and scanning electron microscopy data can be used to characterize the energy transfer rate.

2.
Appl Spectrosc ; 77(6): 557-568, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37097834

RESUMO

A spectral analysis tool has been developed to interactively identify and quantify individual gas-phase species from complex infrared absorbance spectra obtained from laboratory or field data. The SpecQuant program has an intuitive graphical interface that accommodates both reference and experimental data with varying resolution and instrumental lineshape, as well as algorithms to readily align the wavenumber axis of a sample spectrum with the raster of a reference spectrum. Using a classical least squares model in conjunction with reference spectra such as those from the Pacific Northwest National Laboratory (PNNL) gas-phase infrared database or simulated spectra derived from the HITRAN line-by-line database, the mixing ratio of each identified species is determined along with its associated estimation error. After correcting the wavelength and intensity of the field data, SpecQuant displays the calculated mixing ratio versus the experimental data for each analyte along with the residual spectrum with any or all analyte fits subtracted for visual inspection of the fit and residuals. The software performance for multianalyte quantification was demonstrated using moderate resolution (0.5 cm-1) infrared spectra that were collected during the time-resolved infrared photolysis of methyl iodide.


Assuntos
Algoritmos , Software , Espectroscopia de Infravermelho com Transformada de Fourier
3.
Sci Rep ; 11(1): 18348, 2021 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-34526588

RESUMO

Calibration of the gain and digital conversion factor of an EMCCD is necessary for accurate photon counting. We present a new method to quickly calibrate multiple gain settings of an EMCCD camera. Acquiring gain-series calibration data and analyzing the resulting images with the EMCCD noise model more accurately estimates the gain response of the camera. Furthermore, we develop a method to compare the results from different calibration approaches. Gain-series calibration outperforms all other methods in this self-consistency test.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...